©2002-2017 Ulm University, Othmar Marti, pict
[Vorherige Seite] [vorheriges Seitenende] [Seitenende] [Ebene nach oben] [PDF-Datei][Epub-Datei][Andere Skripte]

H.  Leistungen eines DSPs






Sample Rate Memory Number of
Benchmark Program (Hz) or Size Clock
Execution Time (Words) Cycles




20-Tap FIR Filter 500.0 kHz 50 54




64-Tap FIR Filter 190.1 kHz 138 142




67-Tap FIR Filter 182.4 kHz 144 148




8-Pole Cascaded Canonic 540.0 kHz 40 50
Biquad IIR Filter (4 x )




8-Pole Cascaded Canonic 465.5 kHz 45 58
Biquad IIR Filter (5x)




8-Pole Cascaded Transpose 385.7 kHz 48 70
Biquad IIR Filter




Dot Product 444.4 ns 10 12




Matrix Multiply 1.556 μs 33 42
2x2 times 2 x 2




Matrix Multiply 1.259 μs 29 34
3x3 times 3 x 1




M-to-M FFT 98.33 μs 489 2655
64 Point




M-to-M FFT 489.8 μs 1641 13255
256 Point




M-to-M FFT 2.453 ms 6793 66240
1024 Point




P-to-M FFT 92.56 μs 704 2499
64 Point




P-to-M FFT 347.9 μs 2048 9394
256 Point




P-to-M FFT 1.489 ms 7424 40144
1024 Point




Tabelle H.1.: Benchmark-Resultate für den 27 MHz-DSP-Prozessor DSP56001R27[Mot90]



[Vorherige Seite] [vorheriges Seitenende] [Seitenanfang] [Ebene nach oben]
©2002-2017 Ulm University, Othmar Marti, pict  Lizenzinformationen